| CIRCUIT CONTROL DEVICE TYPE | CUTOUT RELAY |
| CURRENT REGULATOR UNIT QUANTITY | 1 |
| CURRENT REGULATOR UNIT TYPE | WIRE WOUND COIL |
| CUT-IN VOLTAGE RATING | 24.0 MINIMUM AND 27.0 MAXIMUM |
| DISTANCE BETWEEN HOLES ALONG WIDTH | 2.875 INCHES NOMINAL |
| DISTANCE BETWEEN HOLES ALONG LENGTH | 5.062 INCHES NOMINAL |
| FIELD RELAY UNIT | NOT INCLUDED |
| MOUNTING HOLE DIAMETER | 0.328 INCHES NOMINAL |
| MOUNTING STYLE | FOUR HOLE RECTANGULAR |
| OUTPUT CURRENT RATING IN AMPS | 18.0 MINIMUM AND 22.0 MAXIMUM |
| OUTPUT VOLTAGE RATING IN VOLTS | 27.5 MINIMUM AND 29.5 MAXIMUM |
| RADIO INTERFERENCE SHIELDING | NOT PROVIDED |
| REVERSE CURRENT OVERLOAD CIRCUIT BREAKER | NOT INCLUDED |
| SHOCK MOUNT | NOT PROVIDED |
| SYSTEM GROUND POLARITY | POSITIVE |
| SYSTEM VOLTAGE RATING | 24.0 |
| TERMINAL ENCASEMENT | NOT ENCASED |
| TERMINAL QUANTITY | 3 |
| TERMINAL TYPE | SCREW |
| VOLTAGE REGULATOR UNIT QUANTITY | 1 |
| VOLTAGE REGULATOR UNIT TYPE | WIRE WOUND COIL |