| CENTER TO CENTER DISTANCE BETWEEN SLOTTED HOLES ALONG LENGTH | 6.000 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN SLOTTED HOLES AND PLAIN HOLES ALONG WIDTH | 6.000 INCHES NOMINAL |
| CIRCUIT CONTROL DEVICE TYPE | CUTOUT RELAY |
| CONDUIT CONNECTION QUANTITY | 3 |
| CURRENT REGULATOR UNIT QUANTITY | 1 |
| CURRENT REGULATOR UNIT TYPE | WIRE WOUND COIL |
| CUT-IN VOLTAGE RATING | 25.0 MINIMUM |
| CUT-IN VOLTAGE RATING | 27.0 MAXIMUM |
| CUTOUT CURRENT RATING IN AMPS | 13.0 MAXIMUM |
| CUTOUT CURRENT RATING IN AMPS | 4.0 MINIMUM |
| CUTOUT VOLTAGE RATING | 14.0 MINIMUM |
| CUTOUT VOLTAGE RATING | 17.0 MAXIMUM |
| DISTANCE BETWEEN HOLES ALONG LENGTH | 6.000 INCHES NOMINAL |
| ENVIRONMENTAL PROTECTION | CORROSION RESISTANT |
| ENVIRONMENTAL PROTECTION | FUNGUS RESISTANT |
| FIELD RELAY UNIT | NOT INCLUDED |
| MOUNTING HOLE DIAMETER | 0.318 INCHES MINIMUM |
| MOUNTING HOLE DIAMETER | 0.338 INCHES MAXIMUM |
| MOUNTING SLOT LENGTH | 0.443 INCHES MINIMUM |
| MOUNTING SLOT LENGTH | 0.463 INCHES MAXIMUM |
| MOUNTING SLOT WIDTH | 0.318 INCHES MINIMUM |
| MOUNTING SLOT WIDTH | 0.338 INCHES MAXIMUM |
| MOUNTING STYLE | TWO PLAIN HOLES TWO SLOTTED HOLES |
| OUTPUT CURRENT RATING IN AMPS | 16.0 MINIMUM |
| OUTPUT CURRENT RATING IN AMPS | 20.0 MAXIMUM |
| OUTPUT VOLTAGE RATING IN VOLTS | 28.0 MINIMUM |
| OUTPUT VOLTAGE RATING IN VOLTS | 29.5 MAXIMUM |
| RADIO INTERFERENCE SHIELDING | PROVIDED |
| REVERSE CURRENT OVERLOAD CIRCUIT BREAKER | NOT INCLUDED |
| SHOCK MOUNT | NOT PROVIDED |
| SYSTEM GROUND POLARITY | NEGATIVE |
| SYSTEM VOLTAGE RATING | 24.0 |
| TERMINAL ENCASEMENT | ENCASED |
| TERMINAL QUANTITY | 4 |
| TERMINAL TYPE | THREADED STUD |
| VOLTAGE REGULATOR UNIT QUANTITY | 1 |
| VOLTAGE REGULATOR UNIT TYPE | WIRE WOUND COIL |