National Stock Number: 3424-01-338-7154
Federal Supply Class: 3424
National Item Identification Number: 013387154
Description: FURNACE,HEAT TREATING,ELECTRIC
Detail: EXCLUDES INDUCTION HEATING.
|
Manufacturer Information:
HL86-P48 | 03250 | LUCIFER FURNACES INC. |
|
Techincal Specification:
DOOR/OPENING LOCATION AND QUANTITY | DOORS IN FRONT,2 | ACCESS OPERATION METHOD | MECHANICALLY OPERATED DOOR | ACCESSORY COMPONENTS AND QUANTITY | OVER-TEMPERATURE SYSTEMS,1;TIMERS,2;SCR POWER SUPPLY,1;230 OR 460 V | CURRENT TYPE | AC | DESIGN TYPE | CONTROLLED ATMOSPHERE FULL MUFFLE OVEN | FURNISHED ITEMS | COUNTERWEIGHT | FREQUENCY RATING | 60.0 HERTZ NOMINAL | INSIDE HEIGHT | 18.000 INCHES NOMINAL | INSIDE LENGTH | 43.000 INCHES NOMINAL | INSIDE WIDTH | 24.000 INCHES NOMINAL | MAXIMUM OPERATING TEMP | 2300.0 FAHRENHEIT | MOUNTING TYPE | FLOOR | OPERATING TEMP RANGE | +1600.0 TO 2300.0 FAHRENHEIT | SPECIAL FEATURES | 3200 LBS;102 IN. HT BY 48 IN. WD 77 IN. LG O/A;SERIES 8000 SPACE SAVER;TWO INDEPENDENTLYCONTROLLED CHAMBERS;UPPER CHAMBER OPER TEMP 2300F,2000F OR 1850F;LOWER CHAMBER OPER TEMP 800F,1250F,1400F OR 1600F;DIGITAL CONTROLLERS;MAGNETIC CONTRACTORS;THERMOCOUPLE ASSEMBLIES;INSTRUMENT AND MOTOR FUSES;PRE-WIRED TO N.E.C.;UPPER CHAMBER INERT PROTECTIVE ATMOSPHERE;LOWER CHAMBER HAS BAFFLES AND RECIRCULATING FAN | PHASE | TWO | WATTAGE RATING IN KILOWATTS | 60.0 | TEMP CONTROL DEVICE TYPE | AUTOMATIC | VOLTAGE IN VOLTS | 230.0 |
|
|