| DUTY CYCLE IN PERCENT | 100 |
| BRAKE POWER REQUIRED | 20.0 HORSEPOWER |
| COMPRESSOR QUANTITY | 2 |
| COMPRESSED GAS COOLING MEDIUM | FRESH WATER |
| COMPRESSOR COOLING MEDIUM | AIR |
| COOLING SYSTEM DESIGN | MIXED |
| CONTROL DEVICE TYPE | AUTOMATIC START-STOP |
| CYLINDER ARRANGEMENT STYLE | "V" DESIGN |
| CYLINDER QUANTITY | 8 |
| DISCHARGE FLOW RATE | 59.000 CUBIC FEET PER MINUTE |
| DISCHARGE PRESSURE | 175.000 POUNDS PER SQUARE INCH GAGE |
| GAS COOLING EQUIPMENT TYPE | LIQUID TYPE AFTERCOOLER AND LIQUID TYPE INTERCOOLER |
| GAS FOR WHICH DESIGNED | AIR |
| FREQUENCY IN HERTZ | 60.0 |
| INTAKE CONNECTION QUANTITY | 2 |
| MOUNTING TYPE | HORIZONTAL TANK |
| PHASE | THREE |
| PRIME MOVER COOLING MEDIUM | AIR |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| RECEIVER TANK CAPACITY | 16.00 CUBIC FEET |
| RECIPROCATING COMPRESSOR DESIGN | DOUBLE ACTING |
| STAGE QUANTITY | 2 |
| UNLOADER TYPE | AUTOMATIC |
| VOLTAGE IN VOLTS AND CURRENT TYPE | 230.0 AC OR 460.0 AC |