CENTRIFUGAL PUMP DESIGN | MIXED FLOW |
CENTRIFUGAL PUMP IMPELLER QUANTITY | 1 |
CENTRIFUGAL PUMP IMPELLER SUCTION TYPE | SINGLE |
COOLING METHOD | BLOWER COOLED |
CURRENT RATING IN AMPS | 12.7 |
CURRENT TYPE | AC |
DISCHARGE CONNECTION QUANTITY | 1 |
DISCHARGE CONNECTION TYPE | ROUND FLANGE |
DISCHARGE PRESSURE | 95.0 POUNDS PER SQUARE INCH GAGE |
FREQUENCY IN HERTZ | 60.0 |
INCLOSURE TYPE | FULLY INCLOSED |
INTAKE CONNECTION QUANTITY | 1 |
INTAKE CONNECTION TYPE | ROUND FLANGE |
MAXIMUM DISCHARGE FLOW RATE | 30.0 GALLONS PER MINUTE |
MEDIA FOR WHICH DESIGNED | WATER, DISTILLED |
MOUNTING TYPE | BASE |
OPERATING SPEED AT RATED CAPACITY | 3540.0 REVOLUTIONS PER MINUTE |
PHASE | THREE |
PRIME MOVER COOLING MEDIUM | AIR |
PRIME MOVER POWER RATING | 7.500 HORSEPOWER |
PRIME MOVER QUANTITY | 1 |
PRIME MOVER TYPE | ELECTRIC MOTOR |
PUMP QUANTITY | 1 |
PUMPING ELEMENT OPERATING POSITION | HORIZONTAL |
SPECIFICATION/STANDARD DATA | 81349-MIL-P-17840-B GOVERNMENT SPECIFICATION |
STAGE QUANTITY | 1 |
TOTAL HEAD | 220.000 FEET |
UNPACKAGED UNIT HEIGHT | 15.500 INCHES NOMINAL |
UNPACKAGED UNIT LENGTH | 30.000 INCHES NOMINAL |
UNPACKAGED UNIT WIDTH | 13.6250 INCHES NOMINAL |
VOLTAGE IN VOLTS | 440.0 |