| END CONNECTION DESIGN | ELBOW FIRST END |
| END FITTING COMPONENT AND MATERIAL | COMPLETE FITTING STEEL ALL ENDS |
| END FLANGE CONSTRUCTION | SOLID FIRST END |
| ANGLE BETWEEN RIGID ELBOW FITTINGS IN DEG | 180.0 |
| BURST TEST PRESSURE | 16000.0 POUNDS PER SQUARE INCH |
| CONNECTION TYPE | RECESSED FLANGE FIRST END |
| CONNECTION STYLE | RECESSED W/GASKET GROOVE FIRST END |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| FLANGE OUTSIDE DIAMETER | 2.000 INCHES NOMINAL FIRST END |
| FLANGE STYLE | ROUND W/ OUT BOLT HOLES FIRST END |
| FLANGE THICKNESS | 0.281 INCHES NOMINAL FIRST END |
| FLOW ANGLE | 90.0 DEGREES FIRST END |
| HYDROSTATIC TEST PRESSURE | 8000.0 POUNDS PER SQUARE INCH |
| INSIDE DIAMETER | 1.000 INCHES NOMINAL |
| INSIDE SURFACE CONDITION | SMOOTH |
| ITEM STRUCTURAL COMPOSITION | BRAIDED TEXTILE YARN FIRST LAYER |
| ITEM STRUCTURAL COMPOSITION | MOLDED RUBBER, CHLOROPRENE OUTER LAYER |
| ITEM STRUCTURAL COMPOSITION | SPIRALLY WRAPPED CORROSION RESISTANT STEEL FABRIC THIRD LAYER |
| ITEM STRUCTURAL COMPOSITION | SPIRALLY WRAPPED CORROSION RESISTANT STEEL FABRIC FIFTH LAYER |
| ITEM STRUCTURAL COMPOSITION | SPIRALLY WRAPPED CORROSION RESISTANT STEEL FABRIC FOURTH LAYER |
| ITEM STRUCTURAL COMPOSITION | SPIRALLY WRAPPED CORROSION RESISTANT STEEL FABRIC SECOND LAYER |
| OPERATING PRESSURE | 4000.0 POUNDS PER SQUARE INCH (PSI) MAXIMUM LOCATION NOT OTHERWISE SPECIFIED |
| OUTER COVERING ENVIRONMENTAL PROTECTION | ABRASION RESISTANT AND OIL RESISTANT AND WEATHERPROOF |
| OUTSIDE DIAMETER | 1.750 INCHES NOMINAL |
| MEASURING METHOD AND LENGTH | 48.000 INCHES NOMINAL OVERALL |
| MINIMUM INSIDE BENDING RADIUS | 14.000 INCHES |
| RECESS DEPTH | 0.250 INCHES NOMINAL FIRST END |
| RECESS DIAMETER | 1.000 INCHES NOMINAL FIRST END |
| SPECIAL FEATURES | INNER CONVEYING TUBE MATERIAL-RUBBER, CHLOROPRENE |
| TEMP RATING | -40.0 FAHRENHEIT AND 212.0 FAHRENHEIT SINGLE RESPONSE |