END CONNECTION DESIGN | ELBOW 2ND END |
END CONNECTION DESIGN | STRAIGHT 1ST END |
END FLANGE CONSTRUCTION | SOLID 2ND END |
END FLANGE CONSTRUCTION | SOLID 1ST END |
BURST TEST PRESSURE | 12000.0 POUNDS PER SQUARE INCH |
CONNECTION STYLE | PLAIN 2ND END |
CONNECTION TYPE | PLAIN FACE FLANGE 2ND END |
CONNECTION TYPE | RECESSED FLANGE 1ST END |
CONNECTION STYLE | RECESSED 1ST END |
CROSS-SECTIONAL SHAPE STYLE | ROUND |
FEATURES PROVIDED | ELECTROSTATIC DISCHARGE CAPABILITY |
FLANGE OUTSIDE DIAMETER | 1.750 INCHES NOMINAL 2ND END |
FLANGE OUTSIDE DIAMETER | 2.250 INCHES NOMINAL 1ST END |
FLANGE STYLE | ROUND W/ OUT BOLT HOLES 1ST END |
FLANGE STYLE | ROUND W/ OUT BOLT HOLES 2ND END |
FLANGE THICKNESS | 0.310 INCHES MINIMUM AND 0.320 INCHES MAXIMUM 2ND END |
FLANGE THICKNESS | 0.370 INCHES MINIMUM AND 0.380 INCHES MAXIMUM 1ST END |
FLOW ANGLE | 30.0 DEGREES 2ND END |
HYDROSTATIC TEST PRESSURE | 6000.0 POUNDS PER SQUARE INCH |
INSIDE DIAMETER | 1.000 INCHES NOMINAL |
INSIDE SURFACE CONDITION | SMOOTH |
LAYER COMPOSITION AND LOCATION | 1ST LAYER BRAIDED WIRE AND 2ND LAYER BRAIDED WIRE AND 3RD LAYER BRAIDED WIRE AND 4TH LAYER BRAIDED COTTON CORD AND OUTER LAYER MOLDED RUBBER, SYNTHETIC |
OUTER COVERING ENVIRONMENTAL PROTECTION | ABRASION RESISTANT AND WEATHERPROOF |
OUTSIDE DIAMETER | 1.656 INCHES NOMINAL |
MAXIMUM OPERATING PRESSURE | 3000.0 POUNDS PER SQUARE INCH |
MEASURING METHOD AND LENGTH | 20.562 INCHES NOMINAL WORKING |
MEDIA FOR WHICH DESIGNED | HYDRAULIC FLUID SINGLE RESPONSE |
MINIMUM INSIDE BENDING RADIUS | 13.000 INCHES |
RECESS DEPTH | 0.385 INCHES MINIMUM AND 0.395 INCHES MAXIMUM 1ST END |
RECESS DIAMETER | 1.500 INCHES NOMINAL 1ST END |
TEMP RATING | -40.0 DEG FAHRENHEIT AND 200.0 DEG FAHRENHEIT SINGLE RESPONSE |