| CONNECTION TYPE | PLAIN FACE FLANGE 1ST END | 
 | PLAIN FACE FLANGE 2ND END | 
| MEDIA FOR WHICH DESIGNED | HYDRAULIC FLUID, WATER BASE SINGLE RESPONSE | 
| MEASURING METHOD AND LENGTH | 23.625 INCHES NOMINAL OVERALL | 
| CROSS-SECTIONAL SHAPE STYLE | ROUND | 
| TEMP RATING | -65.0 DEG FAHRENHEIT AND | 
 | 200.0 DEG FAHRENHEIT SINGLE RESPONSE | 
| MAXIMUM OPERATING PRESSURE | 55.0 POUNDS PER SQUARE INCH | 
| BURST TEST PRESSURE | 225.0 POUNDS PER SQUARE INCH | 
| OUTER COVERING ENVIRONMENTAL PROTECTION | ABRASION RESISTANT AND | 
 | WEATHERPROOF | 
| LAYER COMPOSITION AND LOCATION | 1ST LAYER WOVEN COTTON WITH INTERWOVEN STEEL WIRE AND | 
 | OUTER LAYER MOLDED RUBBER, SYNTHETIC | 
| MINIMUM INSIDE BENDING RADIUS | 18.000 INCHES | 
| FLANGE THICKNESS | 0.370 INCHES MINIMUM AND | 
 | 0.380 INCHES MAXIMUM 1ST END | 
 | 0.360 INCHES MINIMUM AND | 
 | 0.370 INCHES MAXIMUM 2ND END | 
| INSIDE DIAMETER | 3.000 INCHES NOMINAL | 
| OUTSIDE DIAMETER | 3.625 INCHES NOMINAL | 
| INSIDE SURFACE CONDITION | SMOOTH | 
| CONNECTION STYLE | PLAIN W/ GASKET GROOVE (SAE FLANGED HEAD) 1ST END | 
 | PLAIN W/ GASKET GROOVE (SAE FLANGED HEAD) 2ND END | 
| END FLANGE CONSTRUCTION | SOLID 1ST END | 
 | SOLID 2ND END | 
| FLANGE STYLE | ROUND W/ OUT BOLT HOLES 1ST END | 
 | ROUND W/ OUT BOLT HOLES 2ND END | 
| FLANGE OUTSIDE DIAMETER | 4.000 INCHES NOMINAL 1ST END | 
 | 4.000 INCHES NOMINAL 2ND END | 
| END CONNECTION DESIGN | STRAIGHT 1ST END | 
 | ELBOW 2ND END | 
| FLOW ANGLE | 90.0 DEGREES 2ND END |