| MAXIMUM OPERATING PRESSURE | 150.0 POUNDS PER SQUARE INCH |
| HYDROSTATIC TEST PRESSURE | 300.0 POUNDS PER SQUARE INCH |
| BURST TEST PRESSURE | 2800.0 POUNDS PER SQUARE INCH |
| VACUUM IN TORR | 25.4 |
| EXTERIOR COLOR | NATURAL |
| LAYER COMPOSITION AND LOCATION | OUTER LAYER BRAIDED BRONZE WIRE |
| MEASURING METHOD AND LENGTH | 15.800 INCHES NOMINAL OVERALL |
| MINIMUM INSIDE BENDING RADIUS | 5.000 INCHES |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| INSIDE DIAMETER | 0.500 INCHES NOMINAL |
| OUTSIDE DIAMETER | 0.688 INCHES NOMINAL |
| INNER CONVEYING TUBE STYLE | ANNULAR CLOSE-PITCH CORRUGATED |
| CONNECTION TYPE | UNTHREADED EXTERNAL TUBE 1ST END |
| UNTHREADED EXTERNAL TUBE 2ND END |
| END CONNECTION DESIGN | STRAIGHT 1ST END |
| STRAIGHT 2ND END |
| NOMINAL OUTSIDE DIAMETER TUBE ACCOMMODATED | 0.625 INCHES 1ST END |
| 0.500 INCHES 2ND END |
| SPECIAL FEATURES | FIRST END ID 0.379 IN. PORM 0.001 IN. TO A DEPTH OF 0.313 IN.,SECOND END OD 0.375 IN. AND 0.562 IN. FROM END |
| TEST DATA DOCUMENT | 80064-845-1889636 REV-B ASSY AA DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |