END CONNECTION DESIGN | STRAIGHT 1ST END |
BURST TEST PRESSURE | 2000.0 POUNDS PER SQUARE INCH |
CONNECTION TYPE | THREADED EXTERNAL TUBE 1ST END |
CONNECTION STYLE | FLARED 1ST END |
CROSS-SECTIONAL SHAPE STYLE | ROUND |
FEATURES PROVIDED | REUSABLE END FITTINGS |
HYDROSTATIC TEST PRESSURE | 1000.0 POUNDS PER SQUARE INCH |
INSIDE DIAMETER | 1.380 INCHES NOMINAL |
INSIDE SURFACE CONDITION | SMOOTH |
LAYER COMPOSITION AND LOCATION | 1ST LAYER BRAIDED FABRIC AND 2ND LAYER BRAIDED CORROSION RESISTANT STEEL WIRE AND OUTER LAYER RUBBER IMPREGNATED BRAIDED FABRIC |
OUTER COVERING ENVIRONMENTAL PROTECTION | OIL RESISTANT AND OZONE RESISTANT |
OUTSIDE DIAMETER | 1.750 INCHES NOMINAL |
MAXIMUM OPERATING PRESSURE | 500.0 POUNDS PER SQUARE INCH |
MEASURING METHOD AND LENGTH | 18.250 INCHES NOMINAL OVERALL |
MEDIA FOR WHICH DESIGNED | FUEL/OIL, HYDROCARBON SINGLE RESPONSE |
MINIMUM INSIDE BENDING RADIUS | 10.500 INCHES |
NOMINAL THREAD SIZE | 1.875 INCHES 1ST END |
NONDEFINITIVE SPEC/STD DATA | 24 SIZE |
SEAT ANGLE | 37.0 DEGREES 1ST END |
TEMP RATING | -55.0 FAHRENHEIT AND 300.0 FAHRENHEIT SINGLE RESPONSE |
THREAD CLASS | 3A 1ST END |
THREAD DIRECTION | RIGHT-HAND 1ST END |
THREAD QUANTITY PER INCH | 12 1ST END |
THREAD SERIES DESIGNATOR | UN 1ST END |
VACUUM IN TORR | 381.0 |