END CONNECTION DESIGN | ELBOW 1ST END |
END FLANGE CONSTRUCTION | SOLID 1ST END |
BURST TEST PRESSURE | 5000.0 POUNDS PER SQUARE INCH |
CONNECTION TYPE | RAISED FACE FLANGE 1ST END |
CONNECTION STYLE | RAISED SWIVEL 1ST END |
CROSS-SECTIONAL SHAPE STYLE | ROUND |
FEATURES PROVIDED | REUSABLE END FITTINGS |
FLANGE STYLE | RECTANGULAR (INCLUDES SQUARE) 1ST END |
FLOW ANGLE | 45.0 DEGREES 1ST END |
HYDROSTATIC TEST PRESSURE | 2500.0 POUNDS PER SQUARE INCH |
INSIDE DIAMETER | 0.844 INCHES NOMINAL |
INSIDE SURFACE CONDITION | SMOOTH |
LAYER COMPOSITION AND LOCATION | 1ST LAYER BRAIDED CORROSION RESISTANT STEEL WIRE, PARTIAL COVERAGE AND OUTER LAYER BRAIDED CORROSION RESISTANT STEEL WIRE |
OUTSIDE DIAMETER | 1.175 INCHES NOMINAL |
MAXIMUM OPERATING PRESSURE | 1000.0 POUNDS PER SQUARE INCH |
MEASURING METHOD AND LENGTH | 24.000 INCHES NOMINAL OVERALL |
MINIMUM INSIDE BENDING RADIUS | 5.500 INCHES |
OUTER COVERING ENVIRONMENTAL PROTECTION | SOLVENT RESISTANT AND ALCOHOL RESISTANT |
TEMP RATING | -65.0 FAHRENHEIT AND 250.0 FAHRENHEIT SINGLE RESPONSE |