BURST TEST PRESSURE | 800.0 POUNDS PER SQUARE INCH SINGLE RESPONSE |
CROSS-SECTIONAL SHAPE STYLE | ROUND |
INSIDE DIAMETER | 1.250 INCHES NOMINAL |
INSIDE SURFACE CONDITION | SMOOTH |
LAYER COMPOSITION AND LOCATION | 2ND LAYER HELIX WIRE COIL ERR-100 |
LAYER COMPOSITION AND LOCATION | 3RD LAYER BRAIDED TEXTILE YARN ERR-100 |
LAYER COMPOSITION AND LOCATION | 1ST LAYER BRAIDED TEXTILE YARN ERR-100 |
LAYER COMPOSITION AND LOCATION | OUTER LAYER MOLDED RUBBER, SYNTHETIC ERR-100 |
MATERIAL | RUBBER SYNTHETIC TUBE |
HYDROSTATIC TEST PRESSURE | 400.0 POUNDS PER SQUARE INCH SINGLE RESPONSE |
PROPRIETARY CHARACTERISTICS | PACS |
MAXIMUM OPERATING PRESSURE | 200.0 POUNDS PER SQUARE INCH SINGLE RESPONSE |
MEDIA FOR WHICH DESIGNED | FUEL/OIL, HYDROCARBON SINGLE RESPONSE AND WATER SINGLE RESPONSE |
MINIMUM INSIDE BENDING RADIUS | 8.000 INCHES |
OUTSIDE DIAMETER | 2.000 INCHES MAXIMUM |
SPECIFICATION/STANDARD DATA | 81343-SAE J517,100R4 PROFESSIONAL/INDUSTRIAL ASSOCIATION STANDARD |
VACUUM IN TORR | 50.8 |