BURST TEST PRESSURE | 20000.0 POUNDS PER SQUARE INCH |
CONNECTION TYPE | THREADED EXTERNAL TUBE 1ST END |
CONNECTION STYLE | PLAIN 1ST END |
CROSS-SECTIONAL SHAPE STYLE | ROUND |
FITTING COMPONENT AND SURFACE TREATMENT | NIPPLE PASSIVATE ALL ENDS |
FITTING COMPONENT AND SURFACE TREATMENT | SOCKET CADMIUM 2ND END |
INSIDE DIAMETER | 0.437 INCHES NOMINAL |
INSIDE SURFACE CONDITION | SMOOTH |
LAYER COMPOSITION AND LOCATION | 2ND LAYER SPIRALLY LAID STEEL WIRE |
LAYER COMPOSITION AND LOCATION | 3RD LAYER SPIRALLY LAID STEEL WIRE |
LAYER COMPOSITION AND LOCATION | 1ST LAYER BRAIDED STEEL WIRE |
LAYER COMPOSITION AND LOCATION | OUTER LAYER BRAIDED STEEL WIRE |
HYDROSTATIC TEST PRESSURE | 10000.0 POUNDS PER SQUARE INCH |
PROPRIETARY CHARACTERISTICS | PACS |
MAXIMUM OPERATING PRESSURE | 5000.0 POUNDS PER SQUARE INCH |
MEASURING METHOD AND LENGTH | 27.625 INCHES NOMINAL WORKING |
MINIMUM INSIDE BENDING RADIUS | 8.000 INCHES |
NOMINAL THREAD SIZE | 1.750 INCHES 1ST END |
OUTSIDE DIAMETER | 0.812 INCHES NOMINAL |
SPECIAL FEATURES | INNER CONVEYING TUBE MATERIAL-PLASTIC, POLYTETRAFLUOROETHYLENE |
THREAD CLASS | 3A 1ST END |
THREAD DIRECTION | RIGHT-HAND 1ST END |
THREAD QUANTITY PER INCH | 12 1ST END |
THREAD SERIES DESIGNATOR | UN 1ST END |
END CONNECTION DESIGN | STRAIGHT 1ST END |
END FITTING COMPONENT AND MATERIAL | SOCKET STEEL ALL ENDS |