| MATERIAL | STEEL OVERALL |
| SURFACE TREATMENT | CADMIUM OVERALL |
| SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | QQ-P-416,TY 3,CL 2 FED SPEC SINGLE TREATMENT RESPONSE OVERALL |
| MEDIA FOR WHICH DESIGNED | HYDRAULIC FLUID SINGLE RESPONSE |
| MAXIMUM OPERATING PRESSURE | 3000.0 POUNDS PER SQUARE INCH SINGLE RESPONSE |
| MAXIMUM OPERATING TEMP | 121.0 DEG FAHRENHEIT SINGLE RESPONSE |
| CONNECTION TYPE | THREADED EXTERNAL TUBE 1ST END |
| THREADED INTERNAL PIPE 2ND END |
| CONNECTION STYLE | FLARED (TUBE) 1ST END |
| PLAIN (PIPE) 2ND END |
| SEAT ANGLE | 37.0 DEGREES 1ST END |
| NOMINAL PIPE SIZE ACCOMMODATED | 0.375 INCHES 2ND END |
| NOMINAL OUTSIDE DIAMETER TUBE ACCOMMODATED | 0.375 INCHES 1ST END |
| THREAD SERIES DESIGNATOR | UNF 1ST END |
| NPTF 2ND END |
| NOMINAL THREAD SIZE | 0.562 INCHES 1ST END |
| 0.375 INCHES 2ND END |
| THREAD CLASS | 2A 1ST END |
| LEG LENGTH | 1.312 INCHES NOMINAL 1ST END |
| 1.020 INCHES NOMINAL 2ND END |
| FLOW ANGLE | 90.0 DEGREES |
| SPECIFICATION/STANDARD DATA | 96906-MS51506 GOVERNMENT STANDARD |
| SPEC/STD CONTROLLING DATA | |
| MANUFACTURERS CODE | 81349 |
| NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-DTL-18866 |
| MANUFACTURERS CODE | 96906 |
| DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MS51506A6-6 |