4820-00-614-6761 VALVE,CHECK Index 5340-00-614-6763 PLUG,EXPANSION

National Stock Number:
4810-00-614-6762

Federal Supply Class:
4810

National Item Identification Number:
006146762

Description:
VALVE,SOLENOID

Detail:
A valve having two or more ports with valve stem or pilot needle in a normally open or closed position. It is specifically designed to stop or start or change the flow of fluid by means of the magnetic action of an electric coil on a moveable core or plunger. The valve may be equipped with a manual opening or closing device. For items with three or more ports that utilize a reciprocating slide with recess areas which mate with ports in an integral or replaceable ported sleeve, see VALVE (1), LINEAR, DIRECTIONAL CONTROL. It may be inline or cartridge (manifold) design. Excludes VALVE (1), BUTTERFLY.


Manufacturer Information:
16F24C2164AAFGC2081978PARKER-HANNIFIN CORPORATION
16F24C2164AAFGC2093781PARKER-HANNIFIN CORP
8210D404845AUTOMATIC SWITCH COMPANY
8210D4-440VAC60HZ04845AUTOMATIC SWITCH COMPANY


Techincal Specification:
APERTURE DIAMETER1.000 INCHES NOMINAL
CONNECTION TYPETHREADED INTERNAL PIPE ALL ENDS
CONNECTION STYLEPLAIN,OPTIONAL END(PIPE) ALL ENDS
CURRENT RATING IN AMPS0.013
FURNISHED ITEMS AND QUANTITY1 ELECTRICAL CONNECTOR
FLOW CONTROL DEVICE NORMAL OPERATION POSITIONCLOSED
FLOW CONTROL DEVICEDIAPHRAGM
FREQUENCY IN HERTZ60.0
INLET/OUTLET OPERATING PRESSURE DIFFERENTIAL125.0 POUNDS PER SQUARE INCH NOMINAL
MATERIAL DOCUMENT AND CLASSIFICATIONASTM ASSN STD SINGLE MATERIAL RESPONSE BODY
MATERIALCOPPER ALLOY 360 BODY
MATERIALRUBBER BUTADIENE-ACRYLONITRILE CLASS NBR FLOW CONTROL DEVICE
MAXIMUM OPERATING TEMP180.0 FAHRENHEIT SINGLE RESPONSE
MAXIMUM OPERATING PRESSURE250.0 POUNDS PER SQUARE INCH SINGLE RESPONSE
MEDIA FOR WHICH DESIGNEDAIR 3RD RESPONSE
MEDIA FOR WHICH DESIGNEDGAS, INERT 2ND RESPONSE
MEDIA FOR WHICH DESIGNEDWATER, FRESH 1ST RESPONSE
MOUNTING POSITIONHORIZONTAL
NOMINAL THREAD SIZE1.000 INCHES ALL ENDS
PHASESINGLE
SPECIAL FEATURESFOR GENERAL PURPOSE SERVICE
STYLE DESIGNATORSTRAIGHT THRU
THREAD DIRECTIONRIGHT-HAND ALL ENDS
THREAD SERIES DESIGNATORNPT ALL ENDS
VALVE OPERATION METHODSOLENOID
VOLTAGE IN VOLTS AND CURRENT TYPE480.0 AC


Click here to Register for Free 30-day Trial