4810-00-938-2939 VALVE,SOLENOID Index 6105-00-938-2943 ROTOR,MOTOR

National Stock Number:
4810-00-938-2940

Federal Supply Class:
4810

National Item Identification Number:
009382940

Description:
VALVE,SOLENOID

Detail:
A valve having two or more ports with valve stem or pilot needle in a normally open or closed position. It is specifically designed to stop or start or change the flow of fluid by means of the magnetic action of an electric coil on a moveable core or plunger. The valve may be equipped with a manual opening or closing device. For items with three or more ports that utilize a reciprocating slide with recess areas which mate with ports in an integral or replaceable ported sleeve, see VALVE (1), LINEAR, DIRECTIONAL CONTROL. It may be inline or cartridge (manifold) design. Excludes VALVE (1), BUTTERFLY.


Manufacturer Information:
100RA2S370255EMERSON ELECTRIC CO ALCO CONTROLS DIV
100RB25370255EMERSON ELECTRIC CO ALCO CONTROLS DIV
835022A044701365MARINE CORPS LOGISTICS COMMAND TECHNICAL DATA REPOSITORY CUSTOMER SERVICE-MICC LOGISTICS OPERATIONS CENTER
835022A0447-101365MARINE CORPS LOGISTICS COMMAND TECHNICAL DATA REPOSITORY CUSTOMER SERVICE-MICC LOGISTICS OPERATIONS CENTER
108904742M D HOLDINGS LLC DBA SANISERV
100RB2S370255EMERSON ELECTRIC CO ALCO CONTROLS DIV
835022A447-101365MARINE CORPS LOGISTICS COMMAND TECHNICAL DATA REPOSITORY CUSTOMER SERVICE-MICC LOGISTICS OPERATIONS CENTER
S155-170255EMERSON ELECTRIC CO ALCO CONTROLS DIV


Techincal Specification:
CONNECTION TYPEUNTHREADED INTERNAL TUBE ALL ENDS
CONNECTION STYLESOCKET (TUBE) ALL ENDS
CURRENT RATING IN AMPS0.200
FLOW CONTROL DEVICE NORMAL OPERATION POSITIONCLOSED
FLOW CONTROL DEVICENEEDLE OR STEM
FREQUENCY IN HERTZ50.0 AND 60.0
INLET/OUTLET OPERATING PRESSURE DIFFERENTIAL200.0 POUNDS PER SQUARE INCH NOMINAL
MATERIALCOPPER ALLOY BODY
MAXIMUM OPERATING PRESSURE400.0 POUNDS PER SQUARE INCH SINGLE RESPONSE
MOUNTING POSITIONHORIZONTAL OR VERTICAL
NOMINAL OUTSIDE DIAMETER TUBE ACCOMMODATED0.375 INCHES ALL ENDS
PHASESINGLE
STYLE DESIGNATORSTRAIGHT THRU
VALVE OPERATION METHODSOLENOID
VOLTAGE IN VOLTS AND CURRENT TYPE120.0 AC AND 240.0 AC