BONNET ATTACHMENT METHOD | INTEGRAL |
CENTER TO CENTER NOMINAL DISTANCE BETWEEN BOLT HOLES ALONG WIDTH | 2.000 INCHES 1ST END |
CURRENT RATING IN AMPS | 3.000 |
MATERIAL | STEEL CORROSION RESISTING BODY |
MAXIMUM OPERATING PRESSURE | 200.0 POUNDS PER SQUARE INCH SINGLE RESPONSE |
MEDIA FOR WHICH DESIGNED | AIR SINGLE RESPONSE |
SPECIAL FEATURES | MANUFACTURERS SUGGESTED NAME IS MOTOR ACTUATED AIR BUTTERFLY VALVE ASSEMBLY; AIR SERVICE UP TO 371 DEG C; AMBIENT TEMP -65 TO 250 DEG F; OPERATING TIME AT 24 VDC IS 1.0 SEC MAX; DIFFERENTIAL OPERATING PRESSURE BETWEEN SUPPLY AND AMBIENT 200 PSI; ACTUATOR VOLTAGE 17 TO 29 VDC; WT 2.94 LBS |
STYLE DESIGNATOR | STRAIGHT THRU FLANGED ENDS |
SURFACE TREATMENT | PASSIVATE |
VALVE OPERATION METHOD | ELECTRIC MOTOR |
VOLTAGE IN VOLTS AND CURRENT TYPE | 17.0 DC AND 29.0 DC |