National Stock Number: 4820-01-142-9667
Federal Supply Class: 4820
National Item Identification Number: 011429667
Description: VALVE,REGULATING,FLUID PRESSURE
Detail: A valve designed to automatically maintain within close limits a predetermined outlet pressure which may be adjustable within a specified range regardless of the higher fluctuating or constant inlet pressure. It is designed for use with compressed gas(es) and various liquids and may include gauges. It may be inline or cartridge (manifold) design. Excludes REGULATOR, PRESSURE, MEDICAL GAS ADMINISTRATION APPARATUS; REGULATOR, OXYGEN, BAROMETRIC CONTINUOUS FLOW; REGULATOR, OXYGEN DEMAND; REGULATOR, OXYGEN DILUTER DEMAND; and valve(1), fluid pressure regulating, aircraft.
|
Manufacturer Information:
30 2 1/2IN50T10 | 35795 | LESLIE CONTROLS, INC. | 30 2 1/2IN50T100PSI N-510 | 35795 | LESLIE CONTROLS, INC. | N-510 | 35795 | LESLIE CONTROLS, INC. | N-510 30 2 1/2IN 50T100PSI | 35795 | LESLIE CONTROLS, INC. |
|
Techincal Specification:
FILTER | NOT INCLUDED | END CONNECTION QUANTITY | 2 | BODY STYLE | STRAIGHT THRU | MATERIAL | COPPER ALLOY BODY | OUTLET PRESSURE RANGE | 50.0 TO 100.0 POUNDS PER SQUARE INCH | FLOW CONTROL DEVICE | DISK, DUAL, TOP GUIDED | FLOW CONTROL DEVICE MATERIAL | NICKEL COPPER ALLOY, QQ-N-288, COMP B | FIRST END CONNECTION TYPE | PLAIN FACE FLANGE | FIRST END STYLE DESIGNATOR | PLAIN | FIRST END FLANGE SHAPE STYLE | ROUND W/ BOLT HOLES | FIRST END BOLT HOLE QUANTITY | 6 | FIRST END FLANGE OUTSIDE DIAMETER | 6.125 INCHES NOMINAL | FIRST END FLANGE THICKNESS | 0.500 INCHES NOMINAL | FIRST END BOLT HOLE DIAMETER | 0.562 INCHES NOMINAL | FIRST END BOLT CIRCLE DIAMETER | 5.000 INCHES NOMINAL | SECOND END RELATIONSHIP WITH FIRST END | IDENTICAL | FACE TO FACE DISTANCE | 10.937 INCHES NOMINAL | MEDIA FOR WHICH DESIGNED | HYDROCARBON FUELS AND OILS | REGULATION TYPE | AUTOMATIC DOUBLE STAGE | VALVE STEM DESIGN | DOUBLE SEAT | VALVE LOADING METHOD | SPRING |
|
|