National Stock Number: 4920-01-078-5369
Federal Supply Class: 4920
National Item Identification Number: 010785369
Description: TEST STATION,ELECTRICAL-ELECTRON
Detail: A GROUP OF ITEMS INCLUDING A CONSOLE AND PERIPHERAL EQUIPMENT SPECIFICALLY DESIGNED FOR USE IN TESTING ELECTRICAL-ELECTRONIC EQUIPMENT. MAY INCLUDE SELF-TEST CAPABILITIES. SEE TEST STATION, GUIDED MISSILE; FAULT LOCATOR (AS MODIFIED)
|
Manufacturer Information:
21C3901G04 | 07482 | GENERAL ELECTRIC COMPANY |
|
Techincal Specification:
FUNCTIONAL CLASSIFICATION | AA-9.4 | FUNCTIONAL DESCRIPTION | THE AMPLIFIER TEST STAND IS DESIGNED TO TEST OVERHAULED COMPONENTS OF THE VARIABLE JET NOZZLE AND TEMPERATURE CONTROL SYSTEM USED ON THE TURBOJET ENGINE MODELS J85-GE-13/21 | PART NAME ASSIGNED BY CONTROLLING AGENCY | AMPLIFIER TEST STAND AND ENVIRONMENTAL TEST CHAMBER | PORTABILITY METHOD | NONBRAKE TYPE CASTERS | SPECIAL FEATURES | POWER REQUIREMENTS 115VAC, 60HZ, 25 AMP, THREE PHASE AND 440V 60HZ, 20AMP SINGLE PHASE; C/O A TEST STAND 44X26X65.5 IN INCHES AND AN ENVIRONMENTAL CHAMBER 28X44X80 IN INCHES, THE TEST STAND C/O TWO INTEGRAL FLOOR RACK CABINETS THAT CONTAIN POWER SUPPLIES, INSTRUMENTATION, RECORDERS, FIXTURES AN ALTERNATOR DRIVE AND CONTROLS, CABLES AND A STORAGE AREA; TWO ENVIRONMENTAL CHAMBERS ARE INSTALLED WITH CONTROLS ON A FLOOR DESIGN WITH CASTERS, THE CHAMBERS HAVE FORCED AIR CIRCULATION. ONE IS A HOT CHAMBER CAPABLE OF 300 DEG. F, THE OTHER IS A COLD CHAMBER CAPABLE OF MINUS 65 DEG. F WITH COMPONENT HEAT LOADS | UNPACKAGED UNIT LENGTH | 44.000 INCHES NOMINAL | UNPACKAGED UNIT HEIGHT | 65.500 INCHES NOMINAL | UNPACKAGED UNIT WIDTH | 26.000 INCHES NOMINAL |
|
|