ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
AC VOLTAGE RATING | 115.0 VOLTS NOMINAL 1ST OPERATING POWER RQMT |
CRITICALITY CODE JUSTIFICATION | FEAT |
FREQUENCY RATING | 400.0 HERTZ NOMINAL 1ST OPERATING POWER RQMT |
INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
OVERALL HEIGHT | 7.720 INCHES NOMINAL |
OVERALL LENGTH | 15.000 INCHES NOMINAL |
OVERALL WIDTH | 10.270 INCHES NOMINAL |
PHASE | SINGLE 1ST OPERATING POWER RQMT |
RECEIVED SIGNAL FREQUENCY RATING | 5.4 GIGAHERTZ NOMINAL |
RECEIVER BAND QUANTITY | 1 |
RECEIVER CHANNEL QUANTITY | 1 |
SPECIAL FEATURES | E.S.D. CRITICAL UNIT |
SUPPLEMENTARY FEATURES | GROUND CLUTTER SUPPRESSION BASED ON PULSE-TO-PULSE AMPLITUDE; MAX THEORITICAL PRECIP DETECTION 320 NAT MI; MAX DOPPLER TURBULENCE AND MEAN VELOCITY RANGE IS 50 NT MI; BANDWIDTH VARIABLE WITH PULSE WIDTH; PULSE WIDTH 2 TO 20 MICROSEC; PULSE REPETITION FREQ 181 TO 362; IF RESPONSE IS LINEAR; SIGNAL PROCESSOR USES PULSE PAIRS; XMTR OUTPUT POWER IS 200 WATTS PEAK |
TRANSMITTED SIGNAL FREQUENCY RATING | 5.4 GIGAHERTZ NOMINAL |
TRANSMITTER BAND QUANTITY | 1 |
TRANSMITTER CHANNEL QUANTITY | 1 |