5895-00-844-0703 GENERATOR,PULSE Index 5895-00-844-0705 BLANKER,INTERFERENCE

National Stock Number:
5895-00-844-0704

Federal Supply Class:
5895

National Item Identification Number:
008440704

Description:
GENERATOR,SWEEP

Detail:
AN ELECTRONIC DEVICE WHICH APPLIES VOLTAGE OR CURRENT TO THE DEFLECTION ELEMENTS IN A CATHODE RAY TUBE IN A WAY TO MAKE THE DEFLECTION FOR THE ELECTRON BEAM A KNOWN FUNCTION OF TIME OR OTHER DATA BASE, AGAINST WHICH OTHER PERIODICALLY OCCURRING ELECTRICAL PHENOMENA MAY BE EXAMINED, COMPARED, OR MEASURED. IT IS OFTEN REFERRED TO AS A TIMING AXIS OSCILLATOR.


Manufacturer Information:
7093164G103538LOCKHEED MARTIN CORPORATION
7093164G124446GENERAL ELECTRIC COMPANY
TD-517/FPS-680058JOINT ELECTRONICS TYPE DESIGNATION SYSTEM


Techincal Specification:
AVERAGE LIFE MEASUREMENTNOT RATED
BASIC SHAPE STYLERECTANGULAR OR SQUARE
CIRCUIT CONSTRUCTION TYPESOLID STATE
EXTERNAL AC OPERATING VOLTAGE IN VOLTS6.1 NOMINAL SINGLE VOLTAGE
EXTERNAL DC OPERATING VOLTAGE IN VOLTS-140.0 NOMINAL 1ST VOLTAGE
EXTERNAL DC OPERATING VOLTAGE IN VOLTS140.0 NOMINAL 2ND VOLTAGE
EXTERNAL DC OPERATING VOLTAGE IN VOLTS250.0 NOMINAL 3RD VOLTAGE
FREQUENCY PER CHANNEL0.0 HERTZ MINIMUM OPERATING CHANNEL AND 30.0 HERTZ MAXIMUM OPERATING CHANNEL
FUNCTIONAL DESCRIPTIONGENERATES A SWEEP WAVEFORM STARTING AT 100V AND SWEEPING AT A RATE OF 27V PER MILLISECOND; THE SWEEP STARTS WHEN A TRIGGER IS APPLIED AND WILL CONTINUE FOR A MINIMUM OF 2.5 MILLISECONDS; THE SWEEP CAN BE STOPPED AT ANY TIME BY THE APPLICATION OF A STOP-TRIGGER
INCLOSURE TYPEENCASED
IMPEDANCE RATING PER CHANNEL330.000 OHMS OUTPUT CHANNEL
INSTALLATION DESIGNRACK
OUTPUT WAVE SHAPESAWTOOTH
OVERALL HEIGHT1.880 INCHES NOMINAL
OVERALL LENGTH3.750 INCHES NOMINAL
OVERALL WIDTH3.220 INCHES NOMINAL
OPERATING AC FREQUENCY IN HERTZ60.0 NOMINAL SINGLE VOLTAGE
PHASESINGLE
POLARITY PER CHANNELNEGATIVE OUTPUT CHANNEL
PULSE DURATION PER CHANNEL2.500 MILLISECONDS NOMINAL OUTPUT CHANNEL
PULSE PEAK AMPLITUDE PER CHANNEL95.000 VOLTS OUTPUT CHANNEL
PULSE REPETITION RATE PER CHANNEL2.000 PULSES PER SECOND MINIMUM OUTPUT CHANNEL AND 400.000 PULSES PER SECOND MAXIMUM OUTPUT CHANNEL
SIGNAL DATA TYPE PER CHANNELOUTPUT CHANNEL PULSE