ZERO POWER RESISTANCE | 120.000 OHMS |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
INCLOSURE TYPE | ENCAPSULATED |
RELIABILITY INDICATOR | NOT ESTABLISHED |
STYLE DESIGNATOR | ROD |
TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| 30.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| 70.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| 100.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 162.0 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
| 109.0 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
| 57.0 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
| 37.0 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 ALL RESISTANCE-TEMPERATURE POINTS |
BODY LENGTH | 0.625 INCHES MAXIMUM |
BODY OUTSIDE DIAMETER | 0.219 INCHES MAXIMUM |
TERMINAL LENGTH | 1.500 INCHES NOMINAL |
TERMINAL DIAMETER | 0.032 INCHES NOMINAL |
REFERENCE TEMP IN DEG CELSIUS | 25.0 |