BODY LENGTH | 0.585 INCHES NOMINAL |
BODY OUTSIDE DIAMETER | 0.200 INCHES NOMINAL |
TERMINAL LENGTH | 1.500 INCHES NOMINAL |
TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
MAXIMUM CURRENT RATING | 25.00 AMPERES |
ZERO POWER RESISTANCE | 5.600 KILOHMS |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
INCLOSURE TYPE | ENCAPSULATED |
RELIABILITY INDICATOR | NOT ESTABLISHED |
STYLE DESIGNATOR | ROD |
TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
MAXIMUM POWER DISSIPATION RATING | 250.00 MILLIWATTS |
AMBIENT TEMP AT FULL RATED POWER | 100.0 DEG CELSIUS |
MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
THERMAL TIME CONSTANT IN SECONDS | 60.0 |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 5.0 |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | 0.70 |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 10.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| 40.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| 70.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 5.0 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| 6.34 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| 7.84 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0 TO 15.0 ALL RESISTANCE-TEMPERATURE POINTS |