AMBIENT TEMP AT FULL RATED POWER | 25.0 CELSIUS |
BODY LENGTH | 0.270 INCHES MINIMUM AND 0.300 INCHES MAXIMUM |
BODY OUTSIDE DIAMETER | 0.090 INCHES MINIMUM AND 0.110 INCHES MAXIMUM |
CUBIC MEASURE | 0.002 CUBIC INCHES |
INCLOSURE TYPE | HERMETICALLY SEALED |
MAXIMUM OPERATING TEMP | 125.0 CELSIUS |
MAXIMUM POWER DISSIPATION RATING | 250.00 MILLIWATTS |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 2.5 |
RELIABILITY INDICATOR | NOT ESTABLISHED |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0 TO 12.0 3RD RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.0 TO 14.0 2ND RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.0 TO 14.0 4TH RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -17.0 TO 17.0 5TH RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0 TO 20.0 1ST RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0 TO 20.0 6TH RESISTANCE-TEMPERATURE POINT |
SPECIFICATION/STANDARD DATA | 81349-MIL-R-23648/19 GOVERNMENT SPECIFICATION |
STYLE DESIGNATOR | ROD |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.7 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.2 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.7 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.1 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.6 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 4.3 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
ZERO POWER RESISTANCE | 2.200 KILOHMS |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -15.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
TERMINAL DIAMETER | 0.020 INCHES NOMINAL |
TERMINAL LENGTH | 1.200 INCHES MINIMUM |
TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
TEST DATA DOCUMENT | 81349-MIL-R-23648 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
THERMAL TIME CONSTANT IN SECONDS | 60.0 |