AMBIENT TEMP AT FULL RATED POWER | 25.0 CELSIUS |
BODY LENGTH | 0.390 INCHES MINIMUM AND 0.430 INCHES MAXIMUM |
BODY OUTSIDE DIAMETER | 0.120 INCHES MINIMUM AND 0.160 INCHES MAXIMUM |
INCLOSURE TYPE | ENCAPSULATED |
MAXIMUM OPERATING TEMP | 125.0 CELSIUS |
MAXIMUM POWER DISSIPATION RATING | 0.50 MILLIWATTS |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 5.0 |
RELIABILITY INDICATOR | NOT ESTABLISHED |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0 TO 12.0 3RD RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -12.0 TO 12.0 4TH RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.0 TO 14.0 2ND RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -14.0 TO 14.0 5TH RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -17.0 TO 17.0 6TH RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0 TO 20.0 1ST RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0 TO 20.0 7TH RESISTANCE-TEMPERATURE POINT |
STYLE DESIGNATOR | ROD |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.606 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.815 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.706 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.19 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.674 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 1.133 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 4.312 KILOHMS 7TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
ZERO POWER RESISTANCE | 2.200 KILOHMS |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -15.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
TERMINAL DIAMETER | 0.022 INCHES MINIMUM AND 0.028 INCHES MAXIMUM |
TERMINAL LENGTH | 1.250 INCHES MINIMUM |
TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
THERMAL TIME CONSTANT IN SECONDS | 60.0 |