ZERO POWER RESISTANCE | 9.000 KILOHMS |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
INCLOSURE TYPE | ENCAPSULATED |
RELIABILITY INDICATOR | NOT ESTABLISHED |
STYLE DESIGNATOR | ROD |
TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
SURFACE TREATMENT | COPPER TERMINAL |
MAXIMUM POWER DISSIPATION RATING | 250.00 MILLIWATTS |
AMBIENT TEMP AT FULL RATED POWER | 100.0 DEG CELSIUS |
MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
THERMAL TIME CONSTANT IN SECONDS | 54.0 |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | 0.70 |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -75.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| -50.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| -20.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| 10.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| 40.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| 100.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
| 130.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.8 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| 4.9 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| 6.3 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
| 8.9 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
| 11.7 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
| 14.8 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT |
| 18.0 KILOHMS 7TH RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0 TO 10.0 ALL RESISTANCE-TEMPERATURE POINTS |
BODY LENGTH | 0.600 INCHES MAXIMUM |
BODY OUTSIDE DIAMETER | 0.220 INCHES MAXIMUM |
TERMINAL LENGTH | 1.500 INCHES NOMINAL |
TERMINAL DIAMETER | 0.025 INCHES MAXIMUM |
TEST DATA DOCUMENT | 97424-6142K60 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
REFERENCE TEMP IN DEG CELSIUS | 25.0 |