ZERO POWER RESISTANCE | 100.000 KILOHMS |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0 TO 5.0 |
INCLOSURE TYPE | ENCAPSULATED |
RELIABILITY INDICATOR | NOT ESTABLISHED |
STYLE DESIGNATOR | WAFER |
TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
THERMAL TIME CONSTANT IN SECONDS | 3.0 |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 1.4 |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -4.96 |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| -30.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| 0.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| 50.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| 100.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| 150.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 12.3 MEGOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| 2.1 MEGOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| 360.0 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
| 32.7 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
| 5.1 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
| 1.1 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.0 TO 20.0 1ST RESISTANCE-TEMPERATURE POINT |
| -16.0 TO 16.0 2ND RESISTANCE-TEMPERATURE POINT |
| -8.0 TO 8.0 3RD RESISTANCE-TEMPERATURE POINT |
| -8.0 TO 8.0 4TH RESISTANCE-TEMPERATURE POINT |
| -14.0 TO 14.0 5TH RESISTANCE-TEMPERATURE POINT |
| -20.0 TO 20.0 6TH RESISTANCE-TEMPERATURE POINT |
BODY LENGTH | 0.070 INCHES NOMINAL |
BODY WIDTH | 0.075 INCHES MAXIMUM |
BODY HEIGHT | 0.070 INCHES NOMINAL |
TERMINAL LENGTH | 2.000 INCHES MINIMUM |
TERMINAL DIAMETER | 0.010 INCHES NOMINAL |
TEST DATA DOCUMENT | 13499-714-2852 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |