CONNECTOR MANUFACTURER PART NUMBER | 10066-12S-3P |
INCLOSURE TYPE | ENCAPSULATED |
OVERALL LENGTH | 3.500 INCHES NOMINAL |
PROBE DIAMETER | 0.375 INCHES NOMINAL |
PROBE LENGTH | 2.000 INCHES NOMINAL |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -0.8 TO 0.8 1ST RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -1.5 TO 1.5 2ND RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -2.0 TO 2.0 3RD RESISTANCE-TEMPERATURE POINT |
RELIABILITY INDICATOR | NOT ESTABLISHED |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -3.0 TO 3.0 4TH RESISTANCE-TEMPERATURE POINT |
WIDTH ACROSS FLATS | 1.125 INCHES NOMINAL |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 120.4 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 200.6 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 303.48 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 366.48 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
STYLE DESIGNATOR | PROBE |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 200.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 300.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, PLUG |