5905-00-948-7631 RESISTOR,THERMAL Index 5905-00-948-7633 RESISTOR,THERMAL

National Stock Number:
5905-00-948-7632

Federal Supply Class:
5905

National Item Identification Number:
009487632

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
112-751EAJ-B0115801HONEYWELL INTERNATIONAL INC.
GB28J102606BAXTER HEALTHCARE CORPORATION DBA BAXTER BIOTECH DIV TRANSFUSION THERAPIES
GB28J115801HONEYWELL INTERNATIONAL INC.


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER125.0 CELSIUS
BODY LENGTH0.906 INCHES NOMINAL
BODY OUTSIDE DIAMETER0.219 INCHES NOMINAL
INCLOSURE TYPEENCAPSULATED
MAXIMUM CURRENT RATING25.00 AMPERES
MAXIMUM OPERATING TEMP200.0 CELSIUS
MAXIMUM POWER DISSIPATION RATING0.50 WATTS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS7.5
REFERENCE TEMP IN DEG CELSIUS25.0
RELIABILITY INDICATORNOT ESTABLISHED
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-15.0 TO 15.0 ALL RESISTANCE-TEMPERATURE POINTS
STYLE DESIGNATORROD
ZERO POWER RESISTANCE AT SPECIFIED TEMP124.8 OHMS 2ND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP316.8 OHMS 1ST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP72.0 OHMS 3RD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-5.0 TO 5.0
ZERO POWER RESISTANCE10.120 OHMS
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER100.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER50.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER80.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.020 INCHES NOMINAL
TERMINAL LENGTH1.375 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS80.0


Click here to Register for Free 30-day Trial