5905-00-958-9256 RESISTOR,VARIABLE,WIRE WOUND,NON Index 5999-00-958-9261 CONTACT,ELECTRICAL

National Stock Number:
5905-00-958-9260

Federal Supply Class:
5905

National Item Identification Number:
009589260

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
41521L9U5MEASUREMENT SPECIALTIES, INC.
415283186MEAS US LLC DIV TEMPERATURE PRODUCTS GROUP DBA MEASUREMENT SPECIALTIES
QB41J102606BAXTER HEALTHCARE CORPORATION DBA BAXTER BIOTECH DIV TRANSFUSION THERAPIES
5569-00305869RAYTHEON COMPANY
478801-00508719DUCOMMUN LABARGE TECHNOLOGIES, INC
666164-07112436BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER25.0 CELSIUS
BODY LENGTH0.500 INCHES NOMINAL
BODY OUTSIDE DIAMETER0.530 INCHES NOMINAL
CUBIC MEASURE0.110 CUBIC INCHES
INCLOSURE TYPEUNINCLOSED
MAXIMUM OPERATING TEMP150.0 CELSIUS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS2.5
REFERENCE TEMP IN DEG CELSIUS25.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-10.3 TO 10.3 4TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-12.3 TO 12.3 3RD RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-12.2 TO 12.2 5TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-13.6 TO 13.6 6TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-14.4 TO 14.4 2ND RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-15.5 TO 15.5 7TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-16.7 TO 16.7 8TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-18.5 TO 18.5 9TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-19.7 TO 19.7 1ST RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-20.0 TO 20.0 10TH RESISTANCE-TEMPERATURE POINT
RELIABILITY INDICATORNOT ESTABLISHED
ZERO POWER RESISTANCE AT SPECIFIED TEMP12.16 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP130.0 OHMS 10TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP2.16 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP28.25 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP314.0 OHMS 9TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP4.067 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP585.0 OHMS 8TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP73.07 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP730.4 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP946.0 OHMS 7TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
ZERO POWER RESISTANCE10.000 KILOHMS
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS-3.90
STYLE DESIGNATORROD
SURFACE TREATMENTSOLDER TERMINAL
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-20.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-60.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER0.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER100.0 CELSIUS 7TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER120.0 CELSIUS 8TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER150.0 CELSIUS 9TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER20.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER200.0 CELSIUS 10TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER50.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER70.0 CELSIUS 6TH RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.016 INCHES NOMINAL
TERMINAL LENGTH1.375 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS20.0