AMBIENT TEMP AT FULL RATED POWER | 25.0 CELSIUS |
BODY OUTSIDE DIAMETER | 0.510 INCHES NOMINAL |
BODY WIDTH | 0.110 INCHES NOMINAL |
INCLOSURE TYPE | HERMETICALLY SEALED |
OVERALL WIDTH | 0.110 INCHES NOMINAL |
MAXIMUM POWER DISSIPATION RATING | 1.50 WATTS |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 12.0 |
RELIABILITY INDICATOR | NOT ESTABLISHED |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.0 TO 5.0 ALL RESISTANCE-TEMPERATURE POINTS |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 19.1 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 21.5 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 68.4 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 842.0 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -5.0 TO 5.0 |
ZERO POWER RESISTANCE | 1.530 KILOHMS |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -4.83 |
STYLE DESIGNATOR | DISK |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -21.7 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 104.4 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 37.8 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
TERMINAL DIAMETER | 0.032 INCHES NOMINAL |
TERMINAL LENGTH | 2.000 INCHES MINIMUM |
TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |