4920-00-964-1200 INSTALLATION TOOL P Index 4920-00-964-1202 JIG,DRILL,NOSE LAND

National Stock Number:
5905-00-964-1201

Federal Supply Class:
5905

National Item Identification Number:
009641201

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
280MR301P001REVA3B150RAYTHEON COMPANY
280MR301P001REVA49956RAYTHEON COMPANY
280MR301P001REVA54X10RAYTHEON COMPANY
41TF5390634GULTON INDUSTRIES INC


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER25.0 CELSIUS
BODY HEIGHT0.200 INCHES NOMINAL
BODY LENGTH0.200 INCHES NOMINAL
BODY WIDTH0.060 INCHES NOMINAL
INCLOSURE TYPEENCAPSULATED
MAXIMUM OPERATING TEMP150.0 CELSIUS
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS4.0
REFERENCE TEMP IN DEG CELSIUS25.0
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-15.0 TO 15.0 ALL RESISTANCE-TEMPERATURE POINTS
RELIABILITY INDICATORNOT ESTABLISHED
ZERO POWER RESISTANCE AT SPECIFIED TEMP100.0 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP1.0 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP8.5 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-10.0 TO 10.0
ZERO POWER RESISTANCE10.000 KILOHMS
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS-4.90
STYLE DESIGNATORWAFER
SURFACE TREATMENTCOPPER TERMINAL
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER-68.0 FAHRENHEIT 1ST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER122.0 FAHRENHEIT 2ND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER205.0 FAHRENHEIT 3RD RESISTANCE-TEMPERATURE POINT
TERMINAL DIAMETER0.010 INCHES NOMINAL
TERMINAL LENGTH2.000 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS8.0