9999-01-081-0073 RESISTOR,VARIABLE,WIRE WOUND Index 1560-01-081-0075 DOOR,ACCESS,AIRCRAFT

National Stock Number:
5905-01-081-0074

Federal Supply Class:
5905

National Item Identification Number:
010810074

Description:
RESISTOR,VARIABLE,NONWIRE WOUND,

Detail:
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus or minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.


Manufacturer Information:
SM-A-93775580063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION280.0 NOMINAL
ELECTRICAL RESISTANCE PER SECTION50.0 OHMS SINGLE SECTION
ACTUATOR TRAVEL CONTROL FEATURESTOPS
ACTUATOR TYPERECESSED DRIVE WITH SLOT
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER125.0 SINGLE SECTION
BODY HEIGHT0.390 INCHES NOMINAL
BODY LENGTH0.240 INCHES NOMINAL
BODY STYLERECTANGULAR
BODY WIDTH0.360 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL0.100 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS0.200 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS0.100 INCHES NOMINAL
CUBIC MEASURE0.033 CUBIC INCHES
FEATURES PROVIDEDHUMIDITY PROOF
FRAGILITY FACTORMODERATELY RUGGED
MAXIMUM STARTING TORQUE5.00 INCH-OUNCES
MAXIMUM RUNNING TORQUE5.00 INCH-OUNCES
MOUNTING METHODTERMINAL
POWER DISSIPATION RATING PER SECTION IN WATTS85.0 FREE AIR SINGLE SECTION
RELIABILITY INDICATORNOT ESTABLISHED
RESISTANCE TOLERANCE PER SECTION IN PERCENT-10.0 TO 10.0 SINGLE SECTION
ROTARY ACTUATOR TRAVEL IN ANGULAR DEG310.0 NOMINAL
SECTION QUANTITY1
SHAFT BEARING TYPESLEEVE
TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS-100.0 TO 100.0 SINGLE SECTION
TERMINAL LENGTH0.200 INCHES NOMINAL
TERMINAL LOCATIONLOWER ADJACENT SIDE TWO ROWS
TERMINAL TYPE AND QUANTITY3 PIN


Click here to Register for Free 30-day Trial