National Stock Number: 5905-01-128-2910
Federal Supply Class: 5905
National Item Identification Number: 011282910
Description: RESISTOR NETWORK,FIXED,FILM
Detail: An arrangement of multiple fixed resistive elements or discrete resistors permanently encased, encapsulated, or potted together, to form an inseparable unit. The resistive elements, consisting of a thin layer of conductive material deposited on or fused to an insulating base, usually are electrically connected to each other and may be arranged in any circuit configuration. Excludes RESISTOR, FIXED (as modified); RESISTOR ASSEMBLY; RESISTOR NETWORK, FIXED-VARIABLE; and RESISTOR SET, MATCHED.
|
Manufacturer Information:
38 380-025 | D9853 | ROCKWELL COLLINS DEUTSCHLAND GMBH | 43-0026-033 | 34649 | INTEL CORP SALES OFFICE | 5214-394 | 05869 | RAYTHEON COMPANY | 730108-222 | 32602 | NATIONAL COMPUTER SYSTEMS INC FIELD SERVICES DIV | 4308R101-222 | 32997 | BOURNS INC | 4308R-101-222 | 80294 | BOURNS INSTRUMENTS INC |
|
Techincal Specification:
ELECTRICAL RESISTANCE | 2.200 KILOHMS EACH RESISTOR | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 25.0 | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 150.0 | BODY HEIGHT | 0.350 INCHES MAXIMUM | BODY LENGTH | 0.790 INCHES MAXIMUM | BODY WIDTH | 0.090 INCHES MAXIMUM | CUBIC MEASURE | 0.024885 CUBIC INCHES | IDENTICAL VALUE RESISTOR QUANTITY | 7 EACH RESISTOR | INCLOSURE METHOD | ENCAPSULATED | POWER DISSIPATION RATING IN WATTS | 1.300 TOTAL NETWORK | RELIABILITY INDICATOR | NOT ESTABLISHED | RESISTANCE TOLERANCE IN PERCENT | -2.000 TO 2.000 EACH RESISTOR | SCHEMATIC DIAGRAM DESIGNATOR | LADDER NETWORK | STYLE DESIGNATOR | SINGLE INLINE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -150.0 TO 150.0 | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 150.0 | TERMINAL LENGTH | 0.070 INCHES MINIMUM | TERMINAL QUANTITY | 8 | TERMINAL TYPE | PIN | TEST DATA DOCUMENT | 16224-985827 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
|
|