AMBIENT TEMP AT FULL RATED POWER | 25.0 CELSIUS |
BODY OUTSIDE DIAMETER | 0.150 INCHES MAXIMUM |
BODY WIDTH | 0.150 INCHES MAXIMUM |
INCLOSURE TYPE | ENCAPSULATED |
MAXIMUM OPERATING TEMP | 125.0 CELSIUS |
MAXIMUM POWER DISSIPATION RATING | 250.00 MILLIWATTS |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 2.0 |
REFERENCE TEMP IN DEG CELSIUS | 25.0 |
RELIABILITY INDICATOR | NOT ESTABLISHED |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -0.72 TO 0.72 2ND RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -0.55 TO 0.55 1ST RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -1.9 TO 1.9 3RD RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -3.0 TO 3.0 4TH RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.1 TO 5.1 5TH RESISTANCE-TEMPERATURE POINT |
STYLE DESIGNATOR | SPHERICAL |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 120.75 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 20.75 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 365.625 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 47.9375 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 5.09 MEGOHMS 1ST RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
ZERO POWER RESISTANCE | 1.250 MEGOHMS |
SURFACE TREATMENT | SOLDER TERMINAL |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
TERMINAL DIAMETER | 0.01003 INCHES NOMINAL |
TERMINAL LENGTH | 1.500 INCHES MINIMUM |
TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
TEST DATA DOCUMENT | 80063-A3013020 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
THERMAL TIME CONSTANT IN SECONDS | 2.0 |