ZERO POWER RESISTANCE | 100.000 OHMS |
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
INCLOSURE TYPE | ENCAPSULATED |
RELIABILITY INDICATOR | NOT ESTABLISHED |
STYLE DESIGNATOR | DISK |
TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
SURFACE TREATMENT | SOLDER TERMINAL |
AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
MAXIMUM OPERATING TEMP | 150.0 DEG CELSIUS |
THERMAL TIME CONSTANT IN SECONDS | 16.0 |
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 4.0 |
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | -3.90 |
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -60.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| -40.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| -20.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| 0.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| 20.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| 30.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
| 50.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
| 100.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT |
| 125.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT |
| 150.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT |
ZERO POWER RESISTANCE AT SPECIFIED TEMP | 7.304 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| 2.151 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| 730.7 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
| 282.5 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
| 121.6 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
| 82.67 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
| 40.67 OHMS 7TH RESISTANCE-TEMPERATURE POINT |
| 9.46 OHMS 8TH RESISTANCE-TEMPERATURE POINT |
| 5.25 OHMS 9TH RESISTANCE-TEMPERATURE POINT |
| 3.14 OHMS 10TH RESISTANCE-TEMPERATURE POINT |
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -19.7 TO 19.7 1ST RESISTANCE-TEMPERATURE POINT |
| -16.8 TO 16.8 2ND RESISTANCE-TEMPERATURE POINT |
| -14.4 TO 14.4 3RD RESISTANCE-TEMPERATURE POINT |
| -12.3 TO 12.3 4TH RESISTANCE-TEMPERATURE POINT |
| -10.3 TO 10.3 5TH RESISTANCE-TEMPERATURE POINT |
| -10.6 TO 10.6 6TH RESISTANCE-TEMPERATURE POINT |
| -12.2 TO 12.2 7TH RESISTANCE-TEMPERATURE POINT |
| -15.5 TO 15.5 8TH RESISTANCE-TEMPERATURE POINT |
| -16.9 TO 16.9 9TH RESISTANCE-TEMPERATURE POINT |
| -18.0 TO 18.0 10TH RESISTANCE-TEMPERATURE POINT |
BODY OUTSIDE DIAMETER | 0.200 INCHES NOMINAL |
BODY WIDTH | 0.056 INCHES NOMINAL |
TERMINAL LENGTH | 1.000 INCHES MINIMUM |
TERMINAL DIAMETER | 0.020 INCHES MAXIMUM |
TEST DATA DOCUMENT | 15280-43-055238 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
REFERENCE TEMP IN DEG CELSIUS | 25.0 |