4010-01-291-1611 WIRE ROPE ASSEMBLY,SINGLE LEG Index 5910-01-291-1613 CAPACITOR,VARIABLE,GLASS DIELECT

National Stock Number:
5905-01-291-1612

Federal Supply Class:
5905

National Item Identification Number:
012911612

Description:
RESISTOR,THERMAL

Detail:
A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.


Manufacturer Information:
443-0862-00194756THE BOEING COMPANY
AX14051L9U5MEASUREMENT SPECIALTIES, INC.
G65802606BAXTER HEALTHCARE CORPORATION DBA BAXTER BIOTECH DIV TRANSFUSION THERAPIES
AX140583186MEAS US LLC DIV TEMPERATURE PRODUCTS GROUP DBA MEASUREMENT SPECIALTIES
X205890634GULTON INDUSTRIES INC


Techincal Specification:
AMBIENT TEMP AT FULL RATED POWER25.0 CELSIUS
BODY LENGTH0.270 INCHES MINIMUM AND 0.290 INCHES MAXIMUM
INCLOSURE TYPEENCASED
MOUNTING FACILITY NOMINAL SCREW THREAD DIAMETER0.163 INCHES
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
MOUNTING THREAD QUANTITY32 PER INCH
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS4.0
RELIABILITY INDICATORNOT ESTABLISHED
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-1.0 TO 1.0 2ND RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-1.0 TO 1.0 3RD RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-1.0 TO 1.0 4TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT-2.0 TO 2.0 1ST RESISTANCE-TEMPERATURE POINT
SPECIAL FEATURESLEADS-B1ACK POLYTETRAFLUOROETHYLENE INSULATION
SPECIFICATION/STANDARD DATA94756-443-0862 MANUFACTURERS SOURCE CONTROL
WIDTH ACROSS FLATS0.250 INCHES MINIMUM AND 0.270 INCHES MAXIMUM
ZERO POWER RESISTANCE AT SPECIFIED TEMP10.4 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP8.05 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP8.8 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP-2.0 TO 2.0
ZERO POWER RESISTANCE10.485 KILOHMS
ZERO POWER RESISTANCE AT SPECIFIED TEMP3.319 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT
STYLE DESIGNATORBEAD IN MACHINE SCREW
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER25.0 CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER31.6 CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER29.4 CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER56.1 CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
TERMINAL LENGTH13.000 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
THERMAL TIME CONSTANT IN SECONDS3.75


Click here to Register for Free 30-day Trial