5905-01-337-0279 RESISTOR,VARIABLE,NONWIRE WOUND, Index 5905-01-337-0281 RESISTOR,VARIABLE,NONWIRE WOUND,

National Stock Number:
5905-01-337-0280

Federal Supply Class:
5905

National Item Identification Number:
013370280

Description:
RESISTOR,VARIABLE,NONWIRE WOUND,

Detail:
A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus or minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, etc., shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see RESISTOR, ADJUSTABLE. For items with step by step variation, see RHEOSTAT and RESISTOR, STEP BY STEP. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see ATTENUATOR, VARIABLE. Excludes RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; and RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.


Manufacturer Information:
3386S-1-504-T80294BOURNS INSTRUMENTS INC
85168389536FLUKE CORP


Techincal Specification:
ELECTRICAL RESISTANCE PER SECTION500.0 KILOHMS SINGLE SECTION
ACTUATOR TRAVEL CONTROL FEATURESTOPS
ACTUATOR TYPERECESSED DRIVE WITH SLOT
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER70.0 SINGLE SECTION
AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER125.0 SINGLE SECTION
BODY HEIGHT0.365 INCHES MINIMUM AND 0.385 INCHES MAXIMUM
BODY LENGTH0.190 INCHES NOMINAL
BODY STYLERECTANGULAR
BODY WIDTH0.365 INCHES MINIMUM AND 0.385 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL0.150 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS0.300 INCHES NOMINAL
CUBIC MEASURE0.028 CUBIC INCHES
FEATURES PROVIDEDHUMIDITY PROOF
FRAGILITY FACTORMODERATELY RUGGED
MAXIMUM RUNNING TORQUE5.00 INCH-OUNCES
MAXIMUM STARTING TORQUE5.00 INCH-OUNCES
MOUNTING METHODTERMINAL
POWER DISSIPATION RATING PER SECTION IN WATTS0.5 FREE AIR SINGLE SECTION
RELIABILITY INDICATORNOT ESTABLISHED
RESISTANCE TOLERANCE PER SECTION IN PERCENT-10.0 TO 10.0 SINGLE SECTION
SECTION QUANTITY1
SHAFT BEARING TYPEBEARING
TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS-100.0 TO 100.0 SINGLE SECTION
TERMINAL LOCATIONLOWER ADJACENT SIDE SINGLE ROW
TERMINAL LENGTH0.200 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY3 PIN