DISTANCE ACROSS WRENCHING SURFACE FLATS | 0.861 INCHES MINIMUM AND 0.875 INCHES MAXIMUM |
FUNCTIONAL DESCRIPTION | PROVIDES A TEMPERATURE SIGNAL TO THE ECS CONTROLLER; THE CONTROLLER USES THIS SIGNAL TO CONTROL THE OBIGGS HEAT EXCHANGER BYPASS VALVE MIX POINT TEMPERATURE FROM FALLING BELOW 50 DEG F; THE SENSOR IS INSTALLED DOWNSTREAM OF THE OBIGGS HEAT BYPASS VALVE/HEAT EXCHANGER |
PART NAME ASSIGNED BY CONTROLLING AGENCY | TEMPERATURE SENSOR |
OPERATING TEMP RANGE | -20.0 TO 240.0 FAHRENHEIT |
OVERALL LENGTH | 2.800 INCHES NOMINAL |
SPECIAL FEATURES | HERMETICALLY SEALED UNIT CONSISTING OF A SINGLE ISOTHERM-PAIR THERMISTOR FOR REQUIRED ACCURACY OVER THE TEMP RANGE, A METAL ENCLOSED SENSING ELEMENT FOR PROTECTION AND A THREADED BOSS NUT |
STYLE DESIGNATOR | TRANSMITTER, 24V DC |
TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE |
THREAD LENGTH | 0.500 INCHES MINIMUM AND 0.520 INCHES MAXIMUM |