5950-00-136-6246 TRANSFORMER,PULSE Index 5910-00-136-6251 CAPACITOR,FIXED,CERAMIC DIELECTR

National Stock Number:
5910-00-136-6250

Federal Supply Class:
5910

National Item Identification Number:
001366250

Description:
CAPACITOR,FIXED,CERAMIC DIELECTR

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
064-06009150AMPEX DATA SYSTEMS CORP COMPUTER PRODUCTS DIV
064-0601DH76DOA INC
1860104-21505397UNION CARBIDE CORP MATERIALS SYSTEMS DIV
1860104-21516546MEPCO/CENTRALAB A NORTH AMERICAN PHILIPS CO
1860104-21519315HONEYWELL INTL INC DEFENSE AVIONICS SYSTEMS FORMER BENDIX NAVIGATION AND CONTROL SYSTEMS
1860104-21555972HONEYWELL INTL INC DEFENSE AVIONICS SYSTEMS
CK1T104J14158AVX FILTERS
CAC05X7R104J100A16299AVX CORP RALEIGH PLANT
CAC05X7R104K100A16299AVX CORP RALEIGH PLANT
C10A104J16546MEPCO/CENTRALAB A NORTH AMERICAN PHILIPS CO
258236-25737695RAYTHEON COMPANY
267745-823B150RAYTHEON COMPANY
267745-8249956RAYTHEON COMPANY
263C067104X5101B56289SPRAGUE ELECTRIC CO WORLD HQS
EL100AT104J20932ILLINOIS TOOL WORKS INC EMCON DIV
CT17-B-104J50056PIEZOTHERMX CORPORATION
SA301C104JAAS9915KYOCERA AVX COMPONENTS JUAREZ, S. DE R.L. DE C.V.


Techincal Specification:
BODY DIAMETER0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
BODY LENGTH0.405 INCHES MINIMUM AND 0.425 INCHES MAXIMUM
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION0.100 MICROFARADS SINGLE SECTION
INSULATION RESISTANCE AT REFERENCE TEMP1000.0 MEGOHM-MICROFARADS
MATERIALPLASTIC CASE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION100.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
POWER FACTOR AT REFERENCE TEMP IN PERCENT2.5000
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TOLERANCE RANGE PER SECTION-5.00 TO 5.00 PERCENT SINGLE SECTION
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE-15.0 TO 15.0 WITHOUT VOLTAGE APPLIED SINGLE SECTION
TERMINAL DIAMETER0.025 INCHES NOMINAL
TERMINAL LENGTH1.250 INCHES MINIMUM
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT19315-1860104 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)


Click here to Register for Free 30-day Trial