5305-00-230-5113 SETSCREW Index 5360-00-230-5119 SPRING,HELICAL,COMPRESSION

National Stock Number:
5910-00-230-5114

Federal Supply Class:
5910

National Item Identification Number:
002305114

Description:
CAPACITOR,FIXED,PLASTIC DIELECTR

Detail:
A capacitor whose capacitance value cannot be adjusted or varied, having a plastic, plastic film, plasticized (plastic impregnated) paper, or any combination of plastic and paper or plastic and paper films as the dielectric material. The plastic may be one or more types of synthetic compounds such as polyesters, polyfluorides, polycabonates, and the like. It may be a single unit, or consist of two or more fixed units which cannot be separated. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALLIZED, PAPER-PLASTIC DIELECTRIC.


Manufacturer Information:
MIS-13300/1-0318876U S ARMY AVIATION AND MISSILE COMMAND


Techincal Specification:
BODY DIAMETER0.193 INCHES NOMINAL
BODY LENGTH0.687 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION68000.000 PICOFARADS SINGLE SECTION
CASE INSULATION MATERIALPLASTIC
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.2500
FEATURES PROVIDEDHERMETICALLY SEALED CASE
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP1000.0 MEGOHMS
INSULATION RESISTANCE AT REFERENCE TEMP10000.0 MEGOHMS
MIL-STD-1276 WIRE LEAD TYPE DESIGNATORN-2
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION50.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-62.0 CELSIUS MINIMUM AND 100.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL LENGTH1.500 INCHES MINIMUM
TERMINAL SURFACE TREATMENTGOLD
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT18876-MIS13300 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-1.00 TO 1.00 PERCENT SINGLE SECTION