5910-00-237-2572 CAPACITOR,FIXED,PLASTIC DIELECTR Index 5945-00-237-2575 RELAY,ELECTROMAGNETIC

National Stock Number:
5910-00-237-2574

Federal Supply Class:
5910

National Item Identification Number:
002372574

Description:
CAPACITOR,FIXED,PLASTIC DIELECTR

Detail:
A capacitor whose capacitance value cannot be adjusted or varied, having a plastic, plastic film, plasticized (plastic impregnated) paper, or any combination of plastic and paper or plastic and paper films as the dielectric material. The plastic may be one or more types of synthetic compounds such as polyesters, polyfluorides, polycabonates, and the like. It may be a single unit, or consist of two or more fixed units which cannot be separated. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALLIZED, PAPER-PLASTIC DIELECTRIC.


Manufacturer Information:
05PL103FSN12517COMPONENT RESEARCH CO INC
0N144058-1598230NATIONAL SECURITY AGENCY
C95355-150TCV9ARIZONA CAPACITORS, INC
C95355-1532159WEST CAP ARIZONA
917314-2682577RAYTHEON COMPANY


Techincal Specification:
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.2000
BODY DIAMETER0.180 INCHES NOMINAL
BODY LENGTH0.562 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION10000.000 PICOFARADS SINGLE SECTION
CASE INSULATION MATERIALPLASTIC
CASE MATERIALMETAL
FEATURES PROVIDEDHERMETICALLY SEALED CASE
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP1000.0 MEGOHMS
INSULATION RESISTANCE AT REFERENCE TEMP100000.0 MEGOHMS
INTERNAL ELECTRICAL CONNECTION TYPEEXTENDED FOIL
PROPRIETARY CHARACTERISTICSPACS
MIL-STD-1276 WIRE LEAD TYPE DESIGNATORN-2
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION50.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-62.0 DEG CELSIUS MINIMUM AND 100.0 DEG CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL DIAMETER0.025 INCHES NOMINAL
TERMINAL LENGTH1.500 INCHES MINIMUM
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TOLERANCE RANGE PER SECTION-1.00/+1.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial