1560-00-237-9669 SOCK SUBASSEMBLY,RUDDER Index 1560-00-237-9671 SOCK SUBASSEMBLY

National Stock Number:
5910-00-237-9670

Federal Supply Class:
5910

National Item Identification Number:
002379670

Description:
CAPACITOR,FIXED,CERAMIC DIELECTR

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
352250008044H0203THALES NEDERLAND B.V.
5SA4743-10U4338THALES UK LIMITED DBA THALES UK LTDDEFENCE MISSION SYSTEMS
913-3997-00113499ROCKWELL COLLINS, INC.
CK06BX472M81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CK06BX472M96095AVX CORPORATION DBA OLEAN ADVANCED PRODUCTS DIV OLEAN ADVANCED PRODUCTS
6L5224-005-485399D0327SELEX ES GMBH
MILC11015-1981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY HEIGHT0.090 INCHES NOMINAL
BODY LENGTH0.290 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
BODY WIDTH0.290 INCHES NOMINAL
CAPACITANCE VALUE PER SECTION4700.000 PICOFARADS SINGLE SECTION
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.185 INCHES MINIMUM AND 0.215 INCHES MAXIMUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT2.5000
INSULATION RESISTANCE AT REFERENCE TEMP100000.0 MEGOHMS
MATERIALPLASTIC CASE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION200.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE-25.0 TO 15.0 WITH RATED VOLTAGE APPLIED SINGLE SECTION
TERMINAL LENGTH1.250 INCHES MINIMUM
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-11015 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-20.00 TO 20.00 PERCENT SINGLE SECTION