5910-00-249-4922 CAPACITOR,FIXED,PLASTIC DIELECTR Index 5960-00-249-4928 RETAINER,ELECTRON TUBE

National Stock Number:
5910-00-249-4924

Federal Supply Class:
5910

National Item Identification Number:
002494924

Description:
CAPACITOR,FIXED,PLASTIC DIELECTR

Detail:
A capacitor whose capacitance value cannot be adjusted or varied, having a plastic, plastic film, plasticized (plastic impregnated) paper, or any combination of plastic and paper or plastic and paper films as the dielectric material. The plastic may be one or more types of synthetic compounds such as polyesters, polyfluorides, polycabonates, and the like. It may be a single unit, or consist of two or more fixed units which cannot be separated. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALLIZED, PAPER-PLASTIC DIELECTRIC.


Manufacturer Information:
1MDF-1-10202799ARCO ELECTRONICS INC
22501029156289SPRAGUE ELECTRIC CO WORLD HQS
84955-253397NUMAX ELECTRONICS INC
244-102-3353998TRI SOURCE, INC
225P10291WD356289SPRAGUE ELECTRIC CO WORLD HQS
225P1029180183SPRAGUE PRODUCTS CO
A401-210851504RAVEN ELECTRONICS CORP


Techincal Specification:
BODY HEIGHT0.200 INCHES MAXIMUM
BODY LENGTH0.700 INCHES MINIMUM
BODY WIDTH0.300 INCHES MAXIMUM
BODY STYLEW/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
CAPACITANCE VALUE PER SECTION1000.000 PICOFARADS SINGLE SECTION
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.345 INCHES MINIMUM AND 0.405 INCHES MAXIMUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT1.0000
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP25.0 MEGOHM-MICROFARADS
INSULATION RESISTANCE AT REFERENCE TEMP25000.0 MEGOHM-MICROFARADS
MATERIALPLASTIC CASE
NONDERATED OPERATING TEMP-40.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION100.0 DC SINGLE SECTION
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL LENGTH1.687 INCHES NOMINAL
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION