6145-00-358-6700 CABLE Index 5910-00-358-6712 CAPACITOR,FIXED,PAPER DIELECTRIC

National Stock Number:
5910-00-358-6711

Federal Supply Class:
5910

National Item Identification Number:
003586711

Description:
CAPACITOR,FIXED,PAPER DIELECTRIC

Detail:
A capacitor whose capacitance value cannot be adjusted or varied, having paper as the dielectric material. It may be a single unit or consist of two or more fixed units which cannot be seperated. For items whose dielectric material consist of plasticized (plastic impregnated) paper or paper-plastic combinations, see CAPACITOR, FIXED, PLASTIC DIELECTRIC. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALIZED, PAPER-PLASTIC DIELECTRIC.


Manufacturer Information:
0189036-0083299HYSTER-YALE GROUP, INC.
2Y1134505415LINDE LIFT TRUCK CORP.
53260AF14RYAN EQUIPMENT CO INC
312-2144940CUMMINS POWER GENERATION INC.
2Y11345556A6LINDE MATERIAL HANDLING NORTH AMERICA CORP
4097078640MITSUBISHI CATERPILLAR FORKLIFT AMERICA, INC
5359-110AF14RYAN EQUIPMENT CO INC
CA4420AF14RYAN EQUIPMENT CO INC
53260AFL4CHAMPION AEROSPACE LLC
5359-110AFL4CHAMPION AEROSPACE LLC
832-280EXU3AQUA-CHEM, INC.
832-2812793AQUA-CHEM INC CLEAVER-BROOKS DIV
65C35484-118894AIR ARMAMENT CENTER/ EN
65C35484-198750SAN ANTONIO AIR LOGISTICS CENTER
XH340800642HEALE MANUFACTURING CO LLC
MC8B9800853CORNELL-DUBILIER MARKETING INC
CA4420AFL4CHAMPION AEROSPACE LLC
MC8B9814655CORNELL-DUBILIER ELECTRONICS
YD20066289WISCONSIN MOTORS LLC
CA44280063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
BODY DIAMETER0.625 INCHES NOMINAL
BODY LENGTH1.438 INCHES NOMINAL
BODY STYLEW/MTG TAB(S), TERMINAL(S) ON ONE END
CAPACITANCE VALUE PER SECTION0.100 MICROFARADS SINGLE SECTION
FEATURES PROVIDEDMOUNTING HARDWARE AND HERMETICALLY SEALED CASE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION100.0 DC SINGLE SECTION
SCHEMATIC DIAGRAM DESIGNATORELECTRODE(S) GROUNDED TO CASE
TERMINAL TYPE AND QUANTITY1 INSULATED WIRE LEAD W/TERMINAL LUG
TOLERANCE RANGE PER SECTION-10.00 TO 50.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial