5999-00-603-7037 CONTACT,ELECTRICAL Index 5910-00-603-7042 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
5910-00-603-7038

Federal Supply Class:
5910

National Item Identification Number:
006037038

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
M39018/02-062281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39018/02-072281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39018/281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC39018-281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL POLARIZATIONNONPOLARIZED
BODY DIAMETER0.375 INCHES NOMINAL
BODY LENGTH2.297 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION56.000 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALALUMINUM
CASE INSULATION MATERIALPLASTIC
DC LEAKAGE AT REFERENCE TEMP16.000 MICROAMPERES
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT10.0000
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION50.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
SPECIFICATION/STANDARD DATA81349-MIL-C-39018/2 GOVERNMENT SPECIFICATION
TERMINAL DIAMETER0.032 INCHES NOMINAL
TERMINAL LENGTH2.125 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-39018 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 30.00 PERCENT SINGLE SECTION