5910-00-809-8666 CAPACITOR,FIXED,MICA DIELECTRIC Index 5935-00-809-8668 CONNECTOR,PLUG,ELECTRICAL

National Stock Number:
5910-00-809-8667

Federal Supply Class:
5910

National Item Identification Number:
008098667

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
0180-01611MY97AGILENT TECHNOLOGIES, INC.
0180-016128480HEWLETT-PACKARD COMPANY
150D335X0035B256289SPRAGUE ELECTRIC CO WORLD HQS
150D335X0035B2D56289SPRAGUE ELECTRIC CO WORLD HQS
150D335X9035B2-DYS56289SPRAGUE ELECTRIC CO WORLD HQS
5910008098667SCY13E.C.A ETABLISSEMENT CENTRALD'APPROVISIONNEMENT DES FORCES ARMEE
T110B335K035AS05397UNION CARBIDE CORP MATERIALS SYSTEMS DIV
STA56221520FANSTEEL INC.
ST513B335K035N25088SIEMENS CORP
TAAB3.30K35ZG28528ITT INDUSTRIES INC ITT AEROSPACE COMMUNICATIONS DIV EAST
TAAB3.30K35ZG31550L3HARRIS TECHNOLOGIES, INC.
930-217-01889372ROCKWELL INTERNATIONAL CORP NORTH AMERICAN AIRCRAFT OPNS
TAS335K035P1C90201MALLORY SONALERT PRODUCTS, INC.


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
ANODE TYPESOLID
BODY DIAMETER0.185 INCHES NOMINAL
BODY LENGTH0.474 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION3.300 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALTANTALUM
CASE INSULATION MATERIALPLASTIC
DC LEAKAGE AT MAXIMUM OPERATING TEMP8.0 MILLIAMPERES
DC LEAKAGE AT REFERENCE TEMP1.700 MICROAMPERES
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT4.0000
FEATURES PROVIDEDHERMETICALLY SEALED CASE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION35.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-80.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL LENGTH1.500 INCHES NOMINAL
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TOLERANCE RANGE PER SECTION-20.00 TO 20.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial