6240-00-814-7378 LAMP,INCANDESCENT Index 5305-00-814-7381 SCREW,CAP,SOCKET HEAD

National Stock Number:
5910-00-814-7380

Federal Supply Class:
5910

National Item Identification Number:
008147380

Description:
CAPACITOR,FIXED,CERAMIC DIELECTR

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
0831030P2H0 479C18796MURATA ERIE NORTH AMERICA INC STATE COLLEGE OPNS
113-3047-0022373HONEYWELL INTERNATIONAL INC.
4-7PFN150-500VP0RM0-25PCT22701BESTRAN CORP DILECTRON DIVISION
831-030P2H0-479C72982ERIE SPECIALTY PRODUCTS INC
CC50PH4R7C81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
113K3047-00K0668LEONARDO UK LTD
MIL-C-20/1681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC20-1681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY DIAMETER0.280 INCHES NOMINAL
BODY LENGTH0.120 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, RADIAL TERMINALS
CAPACITANCE VALUE PER SECTION4.700 PICOFARADS SINGLE SECTION
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER0.190 INCHES MINIMUM AND 0.310 INCHES MAXIMUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.1500
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP1000.0 MEGOHMS
INSULATION RESISTANCE AT REFERENCE TEMP50000.0 MEGOHMS
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION500.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
QUALITY FACTOR AT REFERENCE TEMP500.0000
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
SPECIFICATION/STANDARD DATA81349-MIL-C-20/16 GOVERNMENT SPECIFICATION
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS-150.0 SINGLE SECTION
TERMINAL DIAMETER0.025 INCHES NOMINAL
TERMINAL LENGTH1.250 INCHES MINIMUM
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-20 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS-60.0 TO 60.0 SINGLE SECTION
TOLERANCE RANGE PER SECTION-0.25 TO 0.25 PERCENT SINGLE SECTION