5910-00-829-3304 CAPACITOR,FIXED,ELECTROLYTIC Index 5910-00-829-3306 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
5910-00-829-3305

Federal Supply Class:
5910

National Item Identification Number:
008293305

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
CL44BK200TP181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC396581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
ANODE TYPESOLID
BODY DIAMETER0.296 INCHES MINIMUM AND 0.328 INCHES MAXIMUM
BODY LENGTH0.657 INCHES MINIMUM AND 0.704 INCHES MAXIMUM
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION20.000 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALTANTALUM
DC LEAKAGE AT MAXIMUM OPERATING TEMP16.0 MILLIAMPERES
DC LEAKAGE AT REFERENCE TEMP4.000 MICROAMPERES
EQUIVALENT SERIES RESISTANCE AT REFERENCE TEMP IN OHMS5.00
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS105.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION60.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
TERMINAL LENGTH2.000 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-3965 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-15.00 TO 50.00 PERCENT SINGLE SECTION