5910-00-855-1191 CAPACITOR,FIXED,ELECTROLYTIC Index 5905-00-855-1194 RESISTOR,VARIABLE,WIRE WOUND,NON

National Stock Number:
5910-00-855-1193

Federal Supply Class:
5910

National Item Identification Number:
008551193

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
10049005-3118876U S ARMY AVIATION AND MISSILE COMMAND
4111957-02905869RAYTHEON COMPANY
4111957-2905869RAYTHEON COMPANY
CS13AF4R7K81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC2665581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
ANODE TYPESOLID
BODY DIAMETER0.185 INCHES NOMINAL
BODY LENGTH0.474 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION4.700 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALTANTALUM
DC LEAKAGE AT REFERENCE TEMP3.000 MICROAMPERES
FEATURES PROVIDEDHERMETICALLY SEALED CASE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION35.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 65.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
SPECIFICATION/STANDARD DATA81349-MIL-C-26655/2 GOVERNMENT SPECIFICATION
TERMINAL DIAMETER0.020 INCHES NOMINAL
TERMINAL LENGTH1.500 INCHES NOMINAL
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-26655 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION